제목 TurboVap® LV 등록일 2018-06-18 11:04:10


TurboVap
® is a second generation product for solvent evaporation which builds on the solid foundations of the historic TurboVap product line and incorporates many new customer driven features. It still features the highly efficient patented gas vortex shearing technology, which is synonymous with the TurboVap brand.

 

This modern design features many new enhancements for quick and effective solvent evaporation, including a well-lit glass tank for much greater visibility, removable/replaceable nozzles on the lid, on- the- fly nozzle adjustment, easily exchangeable manifolds to extend functionality, programmable evaporation flow gradients, easy access drain port and user friendly touch screen interface. The system can be vented from the bench or placed in a fume hood. Because the footprint is noticeably smaller on the modern unit, less space is required.

A novel and innovative feature of the new TurboVap® family is the Multi Rack that can be fully adjusted for a range of tube/vial sizes. By using the series of Multi Racks, the TurboVap LV will accommodate tube/vial sizes from 1.5 mL up to 60 mL. Two versions of the 48 position rack are available to accomodate most common glassware sizes. When used in the 24 position mode, the Multi Rack will accommodate 24 x I-Chem/ ASE/ EPA vials, 24 x 50 mL centrifuge tubes/Greiner or 24 x TurboVap II, 50 mL, 0.5 or 1.0 mL End Point Tubes*.

In addition to the many user-friendly improvements, the new TurboVap LV outperforms its predecessor as well, providing faster evaporation, higher analyte recoveriesand lower RSD’s. 

The new Turbovap LV is design so that it can be easily and quickly converted between the functionality of the traditional LV and II instruments, as well as accomodate Extrahera Automation compatible racks.

* End Point detection not available in this 24 position mode.

Technical Specifications

Evaporation

Gas Supply and Connection

The system can operate using inert gas. Compressed air can be used but is not recommended with some solvents due to the possible risk of explosion. The gas tube supplied with the system has a 6 mm outer diameter. An adapter for connecting a gas tube with an outer diameter of 1/4" can be purchased separately.

Note: There is no regulator for the gas inlet supplied with the system. This can be purchased separately as an optional accessory (P/N 352281SP Air Control Unit and P/N 353480SP Supply Connection Set).

  • Minimum supply pressure: 4 bar (0.4 MPa, 58 PSI).
  • Required supply pressure for full flow capability: 6 bar (0.6 MPa, 87 PSI).
  • Maximum pressure: 9 bar (0.9 MPa, 130 PSI).
  • Required supply flow for full flow capability for each manifold:
    • 48 positions: 200 litres/min
    • 24 positions: 160 litres/min

Water Bath Temperature Range

Ambient to 90°C, ± 2°C accuracy

Temperature Increase

Heating time from 20°C to 55°C is approx. 40 mins.

Gas Flow Range

The maximum gas flow depends on the gas supply pressure and flow, the number of available nozzles and how many that are open. The maximum gas flow for each nozzle:

  • 48 positions: 3.5 litres/min
  • 24 positions: 5.5 litres/min                 

Chemical Resistance

  • Trifluoroacetic acid (TFA) 2%*
  • Trichloroacetic acid (TCA) 2%*
  • Formic acid 5%
  • Acetic acid 10%
  • Butyric acid 5%
  • Phosphoric acid 5%
  • Hydrochloric acid 0.1M*
  • Nitric acid 0.1M*
  • Propionic acid 5%
  • Ammonium Hydroxide 5%
  • Triethylamine (TEA) 5% 

    * Acid Resistant PTFE Systems Only

Racks and Tube Sizes

TurboVap LV multi racks

  • 48 positions for 10-16 mm (OD) x <45 mm (length) mini vials
  • 48 positions for 10-20 mm (OD) x 75-165 mm (length) tubes
  • 24 positions for 21-32 mm (OD) x 75-165 mm (length) tubes

Interfaces

Touch Screen

7 Inch Touch Screen       

Auxiliary

Connection for end-point detection      

System

Fume Hood/Ventilation

The system must be either connected to ventilation system using the exhaust outlet at the rear of the system or placed in a well-ventilated fume hood or an equivalent enclosure to reduce the risk of exposure to harmful solvent vapours. The ventilation system or fume hood must be capable of exhausting 1 m3/min (35.3 ft3/min).

Connection: The exhaust hose supplied with the system is 3.8 meters (12.5 feet) and has a 50.8 mm (2") inner diameter.

Operating Temperature

18°C to 32°C

Storage Temperature

-25°C to 60°C

Humidity

20% to 90% RH (non-condensing)

Electrical Supply

100-127 V and 220-240 V at 50/60 Hz

Fuses

F10A at the power inlet (1 required)

Max Power Consumption

1000 VA

Weight

17 kg (37.5 lbs) when the water bath is empty and maximum 29 kg (63.9 lbs) with deionized water, rack, and tubes.

Dimensions (W x D X H)

400 x 400 x 390 mm (15.7" x 15.7" x 15.4") including the hinges at the side and exhaust at the rear. The height with the lid open is 590 mm (23.2").

Max Sound Level

75 dB(A)

Certifications

CE marked and CB and NRTL certified

공지사항
Cat No. 제품명
414574 Test Tubes (18 x 75 mm, Uncap)
415148 IChem/ASE/EPA Vials Clear 40 mL (28 x 98 mm)
C128512 Test Tube (50 mL, Centrifuge)
C40707 Test Tubes (13 x 100 mm, Uncap)
C40708 Test Tubes (16 x 100 mm, Uncap)
C40709 Test Tubes (20 x 150 mm, Uncap)
C44651 Test Tubes (12 x 75 mm, Uncap)
C44941 Test Tubes (15 mL Conical, Uncap)
C45273 Test Tubes (16 x 125 mm, Uncap)
C47811 Test Tubes (10 mL Conical, Uncap)
C47816 Test Tubes (15 mL, Conical Bottom)
C48985 Test Tubes (10 x 75 mm, Uncap)
414964 TurboVap® LV Multi Rack (48 Positions, 10-20 mm Tubes)
415129 TurboVap® LV Multi Rack (24 Positions, 21-32 mm Tubes)
415408SP TurboVap® LV Manifold (48 Nozzles)
415489 TurboVap® LV Multi Rack (48 Positions, Mini Vials)
416129SP TurboVap® LV Manifold (48 Nozzles) - PTFE Coated
416164SP Replacement Nozzle for TurboVap, Treated
413282 Test Tubes (16 x 75 mm, Uncap)